Keywords: Distribution pricing, Economic regulation, Microgeneration pricing, Ramsey prices, Time-of-use tariff
This paper presents an approach for calculating a tariff for electrical energy distribution systems. The methodology is similar to the standard tariff-calculation method used in Brazil. The approach combines the concepts of time-of-use tariffs and Ramsey prices. The process, initially designed for energy consumers, can be used to establish tariffs for micro-generation units. The resulting regulated distribution tariffs, for both consumer and generation units, has an hourly signal associated with long-run marginal costs. Moreover, while minimizing any loss of social benefits, the tariffs comply with the revenue reconciliation constraint. The proposed approach is applied to a real Brazilian distribution system and compared to the current procedure used by the Brazilian Electricity Regulatory Agency.
Since 1990, the gradual deregulation of the electricity market worldwide has led to greater competition, especially in the generation sector. In contrast, the transmission and distribution sectors are natural monopolies. Hence, as they compete with other electricity generators, distribution companies (DISCOs), in determining cost allocation for transmission and distribution, consider their methodologies to be critical.
The current electricity tariff computes charges separately for generation, transmission, and distribution. However, no one has presented any great change to the methodology of cost allocation applied to the electricity distribution sector, and few studies around the world have addressed this fact (Oliveira-De Jesús et al., 2005; Ponce de Leão and Saraiva, 2003; Sotkiewicz and Vignolo, 2006).
Several criteria go into establishing tariffs. The mechanism complexity of these criteria depends on the attainable aims (Rodriguez Ortega et al., 2010), such as establishing tariffs that, ideally, maximize the welfare of both the customer and the distribution company. We may refer to the achievement of these aims as the attainment of efficiency. According to economic theory, reach efficiency means both to maximize the short-run efficiency and to minimize the costs of the enterprise activities (Varian, 2009). To achieve this combined result, tariffs should be equal to the marginal costs (the so-called first best). If we consider, however, the “prices-equal-to-marginal-costs” rule, only the variable costs will be covered by the resulting revenue; the financing of the fixed part of the total costs would remain pending.
In facing such a financing shortfall, a regulated company needs to adjust the marginal costs (a mark-up) in such a way that the tariffs applied can recover the allowed revenue, or the tariff level (second best; Wilson Robert, 1993). This ensures the stakeholder’s allowed profit. In the literature, this adjustment to reach regulated revenue is referred to as revenue adequacy or revenue reconciliation. Its role is fundamental in allocating the additional system costs so as to provide efficiency and sustainability. The revenue may be adjusted using different approaches. For instance, the Brazilian Electricity Regulatory Agency (ANEEL, in Portuguese), uses a fixed multiplier, considering the demand as inelastic.
One approach, however, produces better results than such others as the fixed adder, fixed multiplier, and reliability sensitive adder; this one approach is the Ramsey Prices approach. Kim and Baughman (1997) showed that, regardless of load elasticity level, Ramsey prices always generated a greater surplus than the other available techniques. In fact, the Ramsey rule has been used in different ways to test the economic efficiency of electricity tariffs. It considers the responsiveness of load to price, which suggests the future behavior of the system (Berry, 2000; Horowitz et al., 1996; Hubert, 2002; Lecinq and Ilic, 1997; Matsukawa et al., 1993; Nahata et al., 2007; Raineri and Giaconi, 2005). Given the established tariff, one may then analyze it in terms of performance (Hayashi et al., 1987; Li and Marangon-Lima, 2008; Naughton, 1989; Steele Santos et al., 2010).
This paper proposes a new approach, based on cost allocation and Ramsey prices, to determining the tariffs in an electrical distribution system. Offering a distinct advantage over earlier approaches, this approach makes it unnecessary to analyze each access. The difference of the methodology discussed by Li and Marangon-Lima (2008) concerns the network approach. Here, we consider a radial distribution system, rendering a simplified network model similar to that of Reneses et al. (2011). Such an approach grows out of the Brazilian regulatory scene. The approach has two steps:
Since Ramsey prices are better for the social welfare, our idea is to use them, instead of a fixed multiplier, when calculating revenue reconciliation. Here, Ramsey prices are used both to maximize the social welfare and to obtain the aforementioned economic signal that will optimize the system’s load. Our intention is for this approach to accommodate the dynamic behavior of loads when responding to price changes. Thus, expected consumer behavior, rather than historic charges, can be used to establish the tariff.
The methodology, tested using a real Brazilian distribution system, induces the optimization of system loading. Since a Brazilian system was used, the ANEEL procedure of obtaining consumer tariffs is initially taken as a benchmark. The remainder of this paper is organized as follows: Section 2 describes the methodology applied to obtain the TOU and the generator unit’s tariffs. Section 3 presents the revenue reconciliation with the help of Ramsey-Price approach. This approach is, in Section 4, applied to an actual distribution company in Brazil. Section 5 lays out the conclusions and final remarks.
ANEEL divides tariff assessment into two phases. It’s how it computes distribution activity tariffs. First it establishes regulatory revenues, i.e., the tariff level; second it allocates this required revenue among the system’s users, i.e., the tariff structure. ANEEL determines the allowed annual regulatory revenue by considering the capital, operating, and maintenance costs. This is a part of the tariff revision process and occurs, on average, every four years. Once the required revenue is so defined, the problem becomes how to collect it from the distribution-network users. How the regulatory revenue is allocated among the system’s users is determined by their contributions to the system’s expansion costs. To determine each user’s contribution, i.e., “the extent of use,” a two-step calculation algorithm is used: first, the system’s users and their network profiles are identified; second, the marginal costs of the power supply are calculated. In this section, we describe this two-step algorithm for cost allocation. It defines the first best, since the marginal cost of power supply is based on long-run incremental power cost. We further consider the allowed revenue when discussing the revenue reconciliation.
In practical terms it is unfeasible to define individual tariffs for each consumer according to its load profile. Thus it is convenient to aggregate load curve profiles into a load curve typology. Each load-curve typology represents a set of consumers (user profiles). The same procedure is used for transformer units when their load curves are also clustered into a network profile. These profiles characterize how the users access the network in terms of load curve (user profiles), and how the transformers are also loaded in terms of load curve (network profiles). The profiles come from the metering data recovered from large and small consumers’, from distribution substations, and from the monthly metering accomplishments of step-down transformers.
The load curves that best outline the demand are then drawn out from each measure obtained. To access the voltage levels of primary or secondary user profiles, the consumers serviced at one level are joined, through a “cluster analysis” algorithm, into N subsets (Aldenderfer and Blashfield, 1984). We must consider the annual consumption at such a level because the typologies are obtained from sample data. The procedure to determine the network profiles is nearly the same as that for the user profiles. The difference is that while the user profiles are adjusted to the annual consumption at the voltage level at which they are connected, the network profiles are adjusted to the annual consumption of the voltage level at which they supply.
New consumers or consumption additions increase the installed capacity. This results in investment costs for improving the capacity service, costs incurred by the distribution company (DISCO). The cost to provide a user an additional power unit, both at the voltage level and at a specific time, is known as the user profile’s marginal cost of power supply (Balasko, 1975). By knowing this marginal cost of power supply, the effective cost incurred by the DISCO can be assigned to each user profile. The obtained tariffs establish the economic signals that guide the users toward rationalizing the use of the distribution network.
This price schedule represents the TOU tariff. Given that the user profiles of a voltage level may be serviced by several network profiles, with demand peaks at different periods, it is important to evaluate the probability of the association between user profile and network profile when their maximum load is observed (Wilson Robert, 1993).
For a voltage level with user profiles supplied by network profiles, the participation of each network profile in the energy that supplies the voltage level is given by:
where is the energy consumption associated with network profile .
A network profile, which is the supplier of the voltage level, at time , may be described as a linear combination of users’ profile and demands at time :
where is the load of a network profile at time ; is the load of a user profile at time ; is a factor representing the share of energy from network profile that supplies user profile .
The is a factor analog to factor in Eq. (1). However, is the user profile ’s share in the energy of the level where it is serviced, as stated in Eq. (3).
Then, the share of energy that flows in each voltage level, given by parameters , , and , may be represented by an energy matrix where the rows stand for the network profile curves and the columns stand for the user profile curves (Table 1).
| User-types 1 | User-types 2 | User-types k | ||
|---|---|---|---|---|
| Network-types 1 | ||||
| Network-types 2 | ||||
| Network-types i | ||||
These factors are determined through an optimization problem. The objective is to minimize the sum of the square of the residuals between the measured network profiles value and the network profiles estimated from Eq. (2). Since decision variables are assumed to be the probability of a user profile supplied by a network profile at peak loads, convexity constraint should be considered for each period . The problem is presented in Eq. (4).
The probability of an occurrence of user profile “k,” being given a user network profile “I,” is given by:
The cost-imposing demands are defined as the ones that occur at the time of highest loading of the network profiles (greater than 0.9 p.u). Thus for a network profile with peak times, the probability of a user profile associated with network profile at their peak times is:
So the probability of a user profile being associated with any network profile that supplies level at a peak-demand time is:
In Eq. (7), indicates all the network profiles that present peak demand (greater than 0.9 p.u.) at time . Hence, the probability of a user being associated with the network profiles at service voltage level is defined for each hour.
It may be inferred that the load responsibility of a user in the network at a certain time is the probability of the user being associated with the network at its peak-load time, multiplied by the factor that quantifies the coincidence of occurrence of a network profile peak with a user profile peak (Pessanha et al., 2001).
Therefore, the load (power) responsibility of a user profile at level at all times of the day is given by:
where is the coincidence factor.
The demand of a user profile , supplied at voltage level , at time , implies a marginal cost of power supply (MCPS) from level to level , given by:
where is the average long-run incremental power cost ($/kW) at level , and is the load-flow proportion factor. The average incremental cost, beyond the scope of this paper, is usually defined by the regulator, based on the DISCOs’ expansion plans. Readers interested in this area are referred to Li and Tolley (2007).
The load-flow proportion is the factor calculated from a simplified one-line diagram for heavy load. Its justification lies in the fact that 1 kW requested at a voltage level does not necessarily flow through all the upstream voltage levels (Pessanha et al., 2001). Note, however, that since the simplified network model is adopted, this power flow approach is used to measure the consumers’ responsibility for system usage (Reneses et al., 2011).
The MCPS is obtained from the users profile served at level . The marginal costs of power supply at this level at time is:
where is the demand of user profile at time .
Then, the marginal cost of power supply at level , at time , , is the sum of the other costs from the service level up to all upstream voltage levels:
The procedures described above were initially conceived to establish tariffs for the consumer units according to the responsibilities of their loads on the distribution system expansion costs. The generation units were considered to establish the load-flow proportion along the voltage levels. The inclusion and exclusion of a generation unit modifies, in the system expansion costs, the responsibility of the load. Thus, from the sensitivity analysis of the marginal costs of power supply, it is possible to establish, according to the variation of the amount of injected energy at each voltage level, the hourly tariffs for the generation units as well. Note the assumption that the generators’ units are marginal and do not change the flow direction among voltage levels.
Note, also, that the cost allocation for consumers and generators defines, say, reference tariffs. These reference tariffs are defined as TOU tariffs and may vary continuously for each price period. These tariffs, however, ignore the allowed revenues. Hence to meet DISCO equilibrium, as we discuss next, revenue reconciliation must be performed.
In the field of electricity distribution, revenue reconciliation is used to adjust the marginal costs (second best) in such a way that the tariffs applied can recover the allowed revenue. This is performed by maximizing economists’ social welfare, given the allowed revenue. In this paper, however, the first-best prices defined in Section 2 are also used as constraints in the second-best computation. These constraints are included in the standard optimization problem approach, described next, to obtain the Ramsey price.
First, the demand functions are established for each user profile at voltage level . The linear demand function is chosen because the expected tariff variation tends to be small and the elasticity is assumed to be all the same (over each consumer group, i.e., industrial, commercial, residential, etc.) (Oliveira-De Jesús et al., 2005). Eq. (12) states the model.
In Eq. (12), denotes the amount of load requested from user profile , at voltage level , considering the price ; denotes the maximum amount of load requested from user profile , at voltage level , when the price is close to zero; denotes the slope of the demand curve of user profile , at voltage level ; denotes the electricity tariff; and denotes the maximum price that the consumer is willing to pay. Note that, once the first best is defined, is a continuously differentiable function of , at each time interval.
Note, also, that may result in a high number. Thus, to obtain a realistic model, the demand curve should be established considering operative limits. It is effective for any other demand curve model (Steele Santos et al., 2009).
Further, the consumer surplus function is defined for each DISCO, integrating Eq. (12) for each user profile identified at voltage level , as shown in Eqs. (13) and (14), and Fig. 1.
In Eq. (14), is the surplus of all typical consumers considered at all voltage levels; and is the access price at interval , identified for user profile , at voltage level . The traditional Ramsey price approach would maximize, constrained by allowed revenue, the consumer surplus, given by Eq. (14). It would define the electricity distribution rates for each group of consumers.
In the approach proposed here, however, the price schedules for demand are now combined with the user profile to predict total revenues at each voltage level (Mitcheell et al., 1978). These revenues define the vertical structure. The ratios among the price periods at each voltage level define the horizontal structure. Besides the horizontal and vertical structures, the regulatory distribution revenue is also used as a constraint to the optimization model in calculating the Ramsey price. Thus, a new optimization problem is established in Eq. (15). It maximizes the consumer surplus subjected to a set of the constraints.
In Eq. (15), is the regulatory revenue, is the horizontal ratio at level L and is the vertical ratio between level and .
Despite this approach reducing the standard Ramsey price method’s ability to improve total surplus, it maintains the TOU structure, and, at the same time, considers load elasticity. Thus, it is important to state that the vertical and horizontal ratios obtained in the first-best computation serve two purposes: to induce the system load optimization, and to allocate, according the load responsibility on the MCPS, the regulatory revenue. Using this procedure, tariffs optimize the use of the system, and maximize the total consumer units’ surplus.
On the other hand, Train (1995) observed that the Ramsey price procedure increases the tariff on low elasticity electricity consumers. At first blush, this seems, for those consumers, an unfair procedure. However, when considering the market elasticity in the tariff computation approach, the consumers’ willingness to pay is quantifiable. Such data may be used to define tariff caps for each set of consumers.
In this section, we use our approach to obtain consumer and generation tariffs using actual data from a Brazilian distribution company. The total load of this DISCO is 5,000 GWh/year, supporting about 800,000 consumer units. The distribution system has five voltage levels. Moreover, to obtain the marginal costs of power supply, we considered 49 and 33 representative profiles of network and user. Table 2 presents the DISCO characteristics.
| Voltage level (kV) | Name level | Networks-type | User-type |
|---|---|---|---|
| 138 | A2 | 3 | 3 |
| 69 | A3 | 3 | 1 |
| 34.5 | A3A | 6 | 1 |
| 13.8 | A4 | 15 | 18 |
| 0.127 | BT | 6 | 26 |
To evaluate the performance of the proposed methodology, the ANEEL procedure is taken as the benchmark. This procedure ignores load elasticity and uses a fixed multiplier to match the allowed revenue. ANEEL compares the revenue obtained by non-adjusted tariffs with the revenue computed in the tariff-revision procedure. The ratio between the non-adjusted and the tariff-revision revenues is then used as the fixed multiplier to obtain the adjusted tariffs.
The MCPS was first computed as described in Section 2.2. Carried out next was the approach to compute tariffs for generation units, described in Section 2.3, and the established regulatory revenue was discussed. The revenue reconciliation was then obtained and compared using both a fixed multiplier (ANEEL tariffs) and an elasticity sensitive adder (Ramsey prices).
The marginal cost of power supply (MCPS) is calculated for each level at hour . In this example, for the voltage level 0.127 kV, there are four other upstream levels. The results are presented in Fig. 2 and Table 3. The MCPS obtained for each voltage level characterizes the cost structure among the referred levels; it is called the vertical structure. It defines the criterion for the regulatory revenue allocation among the various voltage levels of a DISCO, as shown in Table 4.
| Hour | MCPSBT,h | BT | A4 | A3A | A3 | A2 |
|---|---|---|---|---|---|---|
| 1 | 0.59 | 0.54 | 0.04 | 0.00 | 0.00 | 0.00 |
| 2 | 0.66 | 0.61 | 0.05 | 0.00 | 0.00 | 0.00 |
| 3 | 0.71 | 0.66 | 0.05 | 0.00 | 0.00 | 0.00 |
| 4 | 0.73 | 0.68 | 0.05 | 0.00 | 0.00 | 0.00 |
| 5 | 0.71 | 0.66 | 0.05 | 0.00 | 0.00 | 0.00 |
| 6 | 0.61 | 0.57 | 0.04 | 0.00 | 0.00 | 0.00 |
| 7 | 0.03 | 0.00 | 0.03 | 0.00 | 0.00 | 0.00 |
| 8 | 0.03 | 0.00 | 0.03 | 0.00 | 0.00 | 0.00 |
| 9 | 0.02 | 0.00 | 0.02 | 0.00 | 0.00 | 0.00 |
| 10 | 3.56 | 3.53 | 0.02 | 0.00 | 0.00 | 0.00 |
| 11 | 7.47 | 3.55 | 1.24 | 1.31 | 0.06 | 1.31 |
| 12 | 9.28 | 4.19 | 2.18 | 1.56 | 0.00 | 1.35 |
| 13 | 9.38 | 4.16 | 2.14 | 1.75 | 0.00 | 1.33 |
| 14 | 9.66 | 4.38 | 2.15 | 1.78 | 0.00 | 1.35 |
| 15 | 10.49 | 4.60 | 2.75 | 1.78 | 0.00 | 1.35 |
| 16 | 11.00 | 4.58 | 2.93 | 1.79 | 0.34 | 1.36 |
| 17 | 10.63 | 4.31 | 2.82 | 1.80 | 0.34 | 1.36 |
| 18 | 5.86 | 0.33 | 2.36 | 1.80 | 0.00 | 1.36 |
| 19 | 11.24 | 7.29 | 0.24 | 0.48 | 0.00 | 3.24 |
| 20 | 22.46 | 8.62 | 9.15 | 1.08 | 0.50 | 3.10 |
| 21 | 22.07 | 9.01 | 9.03 | 0.49 | 0.49 | 3.05 |
| 22 | 13.01 | 5.91 | 5.35 | 0.00 | 0.46 | 1.28 |
| 23 | 1.90 | 0.43 | 1.02 | 0.00 | 0.45 | 0.00 |
| 24 | 0.72 | 0.50 | 0.00 | 0.00 | 0.23 | 0.00 |
| Level | Revenue | Vertical structure |
|---|---|---|
| BT | R$146,371,702.34 | 86.35% |
| A4 | R$19,425,558.74 | 11.46% |
| A3A | R$344,861.86 | 0.20% |
| A3 | R$14.40 | 0.00% |
| A2 | R$3,370,668.97 | 1.99% |
The MCPS at level at price period may be obtained from an hourly average of the MCPS at level , as shown in Eq. (16).
where is the period length in hours of the price period .
In the case study, higher voltage levels have access tariffs, given in $/kW, and usage tariff, given in $/kWh. However, low voltage presents only usage tariff. Thus, a conversion is needed. For this, the capacity tariffs turn to energy tariffs using the mean load factor for each voltage level, as follows:
where , , and are the usage tariff (in $/MWh), access tariff (in $/kW), and load factor, respectively. Moreover, 720 concerns hours per month.
Table 5 shows the average prices obtained from each of the two time intervals created for this case. Note that an average is used here because only two price intervals can be defined in this regulatory scenario, i.e., peak and off-peak periods. However, when hourly price is permitted, no average computation is needed. The horizontal structure is defined by the MCPS for each period at each voltage level; that is, the relationships among the established price periods are the determining factor. Considering all voltage levels, Table 6 shows the average price of the horizontal structure.
| Price period | CMFBT |
|---|---|
| I — 19 to 22 h | 4.20 |
| II — 0 to 19 and 22 to 0 h | 17.20 |
| Price period 1 | Price period 2 | |
|---|---|---|
| MCPSBT R$/kW | 4.20 | 17.20 |
| horizontal structureBT | 1.00 | 4.10 |
| MCPSA4 R$/kW | 4.43 | 6.34 |
| Horizontal structureA4 | 1.00 | 1.43 |
| MCPSA3A R$/kW | 0.35 | 5.75 |
| Horizontal structureA3A | 1.00 | 16.43 |
| MCPSA3 R$/kW | 4.52 | 7.81 |
| Horizontal structureA3 | 1.00 | 1.73 |
| MCPSA2 R$/Kw | 0.18 | 1.93 |
| Horizontal structureA2 | 1.00 | 10.72 |
The horizontal structures identified at each voltage level define the economic signal among the price periods, so as to optimize system use. Since electricity distribution is a natural monopoly, with marginal costs lower than the average costs of power supply, the sole use of this set of first-best tariffs would result in negative profits for the DISCOs. Thus, it’s necessary to adjust the TOU tariffs initially obtained. Before any adjusting takes place, however, the generation unit’s tariffs must be considered.
The simulation of the Brazilian DISCO indicates that the impact on the MCPS calculated for the loads varies according to the amount of energy injected into the system. These variations may be positive or negative. The tariffs for the generation units may also, due to voltage levels, vary considerably throughout the course of a day. For example, in this case a variation of 10 MW of generation at 13.8 kV (A4) modifies the responsibility of the users for the system-expansion costs. Fig. 3 presents values in terms of tariff differences among the cases with and without the generation.
This difference corresponds to the MCPS for the generation units connected at 13.8 kV. In this case, three price periods are sufficient to reveal that the best way to inject power into the network is by way of a generator. Fig. 4 illustrates the average generators’ prices, obtained during each of the three price periods.
The proposed method adjusts the TOU tariffs for generation units differently than it does for loads. In the case of generation units, the values initially calculated are used. Later, the generation units’ revenue is subtracted from the regulatory revenue established for the DISCO. Therefore, the revenue from the generation units contributes to lowering the tariffs for the consumer units.
As already mentioned, the ANEEL approach takes no account of load elasticity. The approach used for revenue reconciliation is made using the postage-stamp method. That results, in this example, in the surplus and tariffs for the DISCO, given in Tables 7, 8, and 9.
| Level | Surplus |
|---|---|
| Surplus A2 | $ 42,382,782 |
| Surplus A3 | – |
| Surplus A3A | $ 4,586,092 |
| Surplus A4 | $ 1,329,227,026 |
| Surplus BT | $ 3,056,784,437 |
| Surplus Total | $ 4,432,980,337 |
| Voltage Level | Power tariff P1 (T, $/kW) | Power tariff P2 (T, $/kW) | Energy tariff P1 (T, $/MWh) | Energy tariff P2 (T, $/MWh) |
|---|---|---|---|---|
| A2 | 2.63 | 15.96 | 109.16 | 175.75 |
| A3 | 0.0 | 0.0 | 0.0 | 0.0 |
| A3A | 3.37 | 14.06 | 109.16 | 175.75 |
| A4 | 6.64 | 24.60 | 109.16 | 175.75 |
| Voltage Level | Power tariff P1 (T, $/kW) | Power tariff P2 (T, $/kW) | Energy tariff P1 (T, $/MWh) | Energy tariff P2 (T, $/MWh) |
|---|---|---|---|---|
| BT | 3.23 | 17.65 | 109.16 | 109.16 |
The Ramsey price, however, does consider load responsiveness to the price. Thus, the demand curves must be modeled and used for this purpose. To model the demand curves, we used the data containing the price elasticity coefficients, available from the Brazilian Secretariat for Economic Monitoring. It’s important to note that these coefficients, presented in Table 10, are similar to those discussed by Qi et al. (2008). The solution of Eq. (15) is seen in Tables 11, 12, and 13, where the surplus and binomial tariffs are presented.
| Voltage level | Elasticity | Typical load |
|---|---|---|
| A2 | −0.545 | Industrial |
| A3 | −0.545 | Industrial |
| A3A | −0.545 | Industrial |
| A4 | −0.174 | Commercial |
| BT | −0.146 | Residential |
| Level | Surplus |
|---|---|
| Surplus A2 | $ 53,235,263 |
| Surplus A3 | – |
| Surplus A3A | $ 5,703,747 |
| Surplus A4 | $ 1,379,174,639 |
| Surplus BT | $ 3,179,024,450 |
| Surplus Total | $ 4,617,138,098 |
| Voltage Level | Power tariff P1 (T, $/kW) | Power tariff P2 (T, $/kW) | Energy tariff P1 (T, $/MWh) | Energy tariff P2 (T, $/MWh) |
|---|---|---|---|---|
| A2 | 1.81 | 10.98 | 75.14 | 120.98 |
| A3 | 0.0 | 0.0 | 0.0 | 0.0 |
| A3A | 3.48 | 14.52 | 75.14 | 120.98 |
| A4 | 5.31 | 19.67 | 75.14 | 120.98 |
| Voltage Level | Power tariff P1 (T, $/kW) | Power tariff P2 (T, $/kW) | Energy tariff P1 (T, $/MWh) | Energy tariff P2 (T, $/MWh) |
|---|---|---|---|---|
| BT | 3.18 | 17.37 | 75.14 | 75.14 |
One can see from Tables 7 and 11 that, as a result of load responsiveness to price, a greater total surplus exists in the distribution system. Further, Tables 12 and 13 show that, when the elasticity sensitive adder is considered, the consumer tariff may be reached. Thus, the elasticity sensitivity adder on revenue reconciliation provides greater social welfare. Moreover, if we ignore consumer ability to respond to price changes with our modeling tariff (as with the fixed multiplier approach), then we also ignore our ability to modulate load, and thereby postpone investment.
Using Ramsey prices, as described earlier, to compute the revenue reconciliation improves the surplus by 4.15%, thereby reducing consumer tariffs. Moreover, the energy consumption is increased by 2.5%, as shown in Table 14.
| Fixed multiplier (MWh) | Elasticity sensitive adder (MWh) | % | |
|---|---|---|---|
| Energy yearly | 4,920,210 | 5,043,318 | 2.50 |
| Energy A2 | 189,193 | 196,338 | 3.78 |
| Energy A3 | 0 | 0 | |
| Energy A3A | 29,302 | 31,762 | 8.40 |
| Energy A4 | 1,004,913 | 1,049,731 | 4.46 |
| Energy BT | 3,696,802 | 3,765,487 | 1.86 |
This study described a methodology to compute tariffs for distribution systems. It was conceived from an analysis of international tariff calculation practices of publicly-regulated services. This study addressed some of the drawbacks of Brazil’s current methodology. Considering that Brazilian tariffs are established every four years, we developed a model capable of considering the dynamic behavior of load when it is responding to price changes. The procedure proposed here produces economic signals which, using a two-step algorithm based on TOU and Ramsey prices, induce the system-loading optimization. It initially calculates first-best tariffs from the TOU type and then includes the generation tariffs. Finally, it maximizes the consumer surplus, and satisfies the revenue reconciliation — the second-best tariffs. Thus, the loading optimization and revenue reconciliation are computed separately.
Recall that Brazil’s model for revenue reconciliation concerns a fixed multiplier. Such a model ignores the ability of consumers to modulate with price changes. However, evidence exists that alternative approaches produce better results, improving the social welfare. Thus, based on these insights, we present a revenue reconciliation approach that considers both consumers’ elasticity and the constraints of the regulatory scene.
We applied the approach to a real distribution system. The consumer surplus was used as a way of gauging the improvement of the social welfare and then compared to the actual procedure applied by ANEEL in Brazil.
Since the methodology proposed optimizes system loading, the system operation is more efficient, reducing both technical and commercial losses. The behavior of technical losses depends directly on the system load. Thus, the mitigation of peak period energy usage avoids high active power losses in the system. In addition, when the load elasticity is considered in the tariff computation approach, it maintains tariffs within a range that consumers are willing to pay. In developing countries, like say Brazil, commercial losses may reach up to 40% in a DISCO. Hence, any approach that reduces commercial losses plays an important role in the tariff computation model.
Despite the proposed method reducing the ability to compute social welfare (compared to standard Ramsey prices), it reaches the target sought here (produces economic signals, optimizes system loading, and improves the social surplus). Moreover, the simulations carried out for a real Brazilian distribution company indicate that the joint use of the concepts of both TOU tariffs and Elasticity Sensitive Adder (Ramsey prices) bring significant advantages over the revenue reconciliation mechanism used by the Brazilian Electricity Regulatory Agency. This study has shown that by utilizing Ramsey prices, the two-step algorithm proposed produces lower consumer tariffs and may increase energy consumption all in addition to generating a greater surplus.
Aldenderfer, M.S., Blashfield, R.K., 1984. Cluster Analysis, Series: Quantitative Applications in the Social Sciences. SAGE Publications.
Balasko, Y., 1975. Optimal Forms of Electricity Tariffs. Conference on Electricity Tariffs, Madrid.
Berry, S.K., 2000. Stranded costs, access charges, and Ramsey pricing in the U.S. electric utility Brazilian Secretariat for Economic Monitoring web site: http://www.seae.fazenda.gov.br/industry Q. Rev. Econ. Finance 40, 503–517.
Hayashi, P.M., Sevier, M., Trapani, J.M., 1987. An analysis of pricing and production efficiency of electric utilities by mode of ownership. In: Crew, M.A. (Ed.), Regulation Utilities in an Era of Deregulation. Macmillan, London, pp. 111–136.
Horowitz, I., Seeto, D., Woo, C.K., 1996. Ramsey pricing of electricity under unknown bypass costs. Energy J. 17, 59–77.
Hubert, F., 2002. Cross subsidies in Russian electric power tariffs: not as bad as their reputation. [Online]. Available at: Higher School of Economics, Moscow http://www2.wiwi.hu-berlin.de/hns/publications/cross-sub-russian-tariff.PDF. accessed on July 15th, 2011.
Kim, B.H., Baughman, M.L., 1997. The Economic Efficiency Impacts of Alternatives for Revenue Reconciliation. IEEE Trans. Power Syst. 12 (3).
Lecinq, B.S., Ilic, M.D., 1997. Peak-load pricing for electric power transmission. 1997 Proceedings of the Thirtieth Hawaii International Conference on System Science, pp. 624–633.
Li, F., Marangon-Lima, J.W., 2008. Network Charges for Micro-Generation. IEEE General Meeting, Paper 08GM1519.
Li, F., Tolley, D.L., 2007. Long-Run Incremental Cost Pricing Based on Unused Capacity. IEEE Trans. Power Syst. 22 (4), 1683–1689 (Nov.).
Matsukawa, I., Seishi, M., Takako, N., 1993. An empirical analysis of Ramsey pricing in Japanese electric utilities. J. Jpn. Int. Econ. 7, 256–276.
Mitcheell, B.M., et al., 1978. Peak-Load Pricing European Lessons for U.S. Energy Policy. Ballinger Publishing Company, pp. 73–74.
Nahata, B., Izyumov, A., Busygin, V., Mishura, A., 2007. An application of Ramsey model in transition economy: a Russian case study. Energy Econ. 29, 105–125.
Naughton, M.C., 1989. Regulatory preferences and two-Part tariffs: the case of electricity. South. Econ. J. 55, 743–758.
Oliveira-De Jesús, P.M., Ponce de Leão, M.T., Yusta, J.M., Khodr, H.M., Urdaneta, A.J., 2005. Uniform Marginal Pricing for the Remuneration of Distribution Networks. IEEE Trans. Power Syst. 20 (3).
Pessanha, J.F.M., Velasquez, R.M.G., Passos Júnior, R., Melo, A.C.G., Caldas, R.P., Tanure, J.E.P., Steele Santos, P.E., 2001. Methodology and Application for Computation of Supply Marginal Cost and Consumer Tariff of Distribution System (in Portuguese) Latin America Power & Gas 2001.
Ponce de Leão, M.T., Saraiva, J.T., 2003. Solving the Revenue Reconciliation Problem of Distribution Network Providers Using Long–Term Marginal Prices. IEEE Trans. Power Syst. 18 (1).
Raineri, R., Giaconi, P., 2005. Price and access charge discrimination in electricity distribution: an application to the Chile case. Energy Econ. 27, 771–790.
Qi, F., Zhang, L., Wei, B., Que, G., 2008. An Application of Ramsey Pricing in Solving the Cross-subsidies in Chinese Electricity Tariffs, DRPT2008 6-9 Nanjing China.
Reneses, J., Gomez, T., Rivier, J., Angarita, J.L., 2011. Electricity tariff design for transition economies: Application to the Libyan power system. Energy Econ. 33 (1), 33–43.
Rodriguez Ortega, M.P., Perez-Arriaga, J.I., Abbad, J.R., Gonzalez, J.P., 2010. Distribution network tariffs: A closed question? (2008). Energy Policy 36 (5), 1712–1725.
Sotkiewicz, P.M., Vignolo, J.M., 2006. Allocation of Fixed Costs in Distribution Networks With Distributed Generation. IEEE Trans. Power Syst. 21 (2).
Steele Santos, P.E., Galvão, L., Leite Ferreira, T.G., Marangon Lima, J.W., Leme, R.C., 2009. Distribution Tariff Computation: Revision and Improvement. Symposium of Specialists in Electric Operational and Expansion Planning (SEPOPE), Belem-PA, Brazil.
Steele Santos, P.E., Galvão, L., Souza, H., Leme, R.C., 2010. Efficiency of Tariff Structure Changes. 7th International Conference on the European Energy Market, Madrid.
Train, K.E., 1995. Optimal Regulation. The MIT Press.
Varian, Hal.R., 2009. Intermediate Microeconomic, 8th ed. W. W. Norton & Company.
Wilson Robert, B.R., 1993. Nonlinear Pricing. Oxford University Press.
* Originally published in Energy Economics 34 (2012) 468–475.